EP-001: Redfish Power Monitoring Support

  • Status: Implemented
  • Maturity: Experimental
  • Author: Sunil Thaha
  • Created: 2025-08-14
  • Updated: 2025-08-28

Summary

Redfish BMC power monitoring has been added to Kepler as an experimental feature, providing platform-level power consumption data that complements existing RAPL CPU monitoring for complete server power visibility.

Problem

Kepler currently measures only CPU power via Intel RAPL, missing:

  • Platform power (PSU, cooling, storage, network)
  • Multi-vendor support (AMD, ARM systems)
  • BMC integration capabilities already present in data centers

Goals

  • Add Redfish BMC power monitoring capability
  • Support Kubernetes, bare metal, and standalone deployments
  • Integrate with existing Kepler architecture
  • Maintain security best practices

Non-Goals

  • Replace RAPL monitoring (complementary)
  • Support non-Redfish protocols (IPMI) initially
  • Implement power control features
  • Advanced resilience patterns in v1

Solution

Add platform service layer collecting BMC power data via Redfish, exposed through Prometheus collectors separately from CPU power attribution.

C4Container
    title Container Diagram - Kepler Power Monitoring

    Person(user, "User", "Prometheus/Grafana")

    Container_Boundary(kepler, "Kepler") {
        Component(rapl, "RAPL Reader", "Go", "CPU power")
        Component(redfish, "Redfish Client", "Go", "Platform power")
        Component(monitor, "Power Monitor", "Go", "Attribution")
        Component(platform, "Platform Collector", "Go", "Platform metrics")
        Component(exporter, "Prometheus Exporter", "Go", "Metrics endpoint")
    }

    System_Ext(bmc, "BMC", "Redfish API")
    System_Ext(kernel, "Linux", "RAPL sysfs")

    Rel(rapl, kernel, "Reads")
    Rel(redfish, bmc, "Queries")
    Rel(monitor, rapl, "Uses")
    Rel(platform, redfish, "Uses")
    Rel(exporter, monitor, "Collects")
    Rel(exporter, platform, "Collects")
    Rel(user, exporter, "Scrapes")

Node Identification

Nodes are automatically identified using the following priority:

  1. CLI flag: --experimental.platform.redfish.node-name=worker-1
  2. Configuration: experimental.platform.redfish.nodeName in config.yaml
  3. Kubernetes node name: Automatically detected when Kubernetes is enabled
  4. Hostname fallback: System hostname used if no explicit identifier provided
# Explicit node name
kepler --experimental.platform.redfish.node-name=worker-1

# Or automatic resolution from Kubernetes node name
kepler --kube.enabled --kube.node-name=worker-1

Configuration Example:

# config.yaml
experimental:
  platform:
    redfish:
      nodeName: worker-1  # Optional - will auto-resolve to kube.node or hostname if not provided
flowchart LR
    A[Node Start] --> B{Node ID?}
    B -->|Yes| C[Load BMC Config]
    B -->|No| D[RAPL Only]
    C --> E{BMC Found?}
    E -->|Yes| F[Connect & Monitor]
    E -->|No| D

Implementation

Package Structure

graph TD
    subgraph "internal/"
        A[platform/redfish/<br/>service.go<br/>config.go<br/>client.go]
        B[exporter/prometheus/<br/>collector/<br/>platform_collector.go]
    end
    A --> B

Service Interfaces

Implements standard Kepler patterns:

  • service.Initializer: Configuration and BMC connection setup
  • service.Shutdowner: Clean resource release and client disconnection

Implementation Details

Simplified On-Demand Architecture with Caching:

  • Power(): synchronous method returning detailed PowerControl readings from all chassis
  • Simple staleness-based caching to reduce BMC API calls
  • Individual PowerControl entry exposure with detailed labeling (chassis_id, power_control_id, power_control_name)
  • BMC API calls only when cached data is stale or unavailable

Service Lifecycle:

  • Init(): Establishes BMC connection, validates credentials
  • Shutdown(): Disconnects from BMC

Configuration

Kepler Config Structure:

type Platform struct {
    Redfish Redfish `yaml:"redfish"`
}

type Redfish struct {
    Enabled     *bool         `yaml:"enabled"`
    NodeName    string        `yaml:"nodeName"`
    ConfigFile  string        `yaml:"configFile"`
    HTTPTimeout time.Duration `yaml:"httpTimeout"` // HTTP client timeout for BMC requests
}

CLI Flags:

--experimental.platform.redfish.enabled=true
--experimental.platform.redfish.node-name=worker-1
--experimental.platform.redfish.config=/etc/kepler/redfish.yaml
# Note: httpTimeout is configuration-only (not exposed as CLI flag)

Main Configuration (hack/config.yaml):

# ... existing config sections ...

experimental:
  platform:
    redfish:
      enabled: true
      nodeName: "worker-1"  # Node identifier for BMC mapping
      configFile: "/etc/kepler/redfish.yaml"
      httpTimeout: 5s     # HTTP client timeout for BMC requests

BMC Configuration (/etc/kepler/redfish.yaml):

The configuration separates node-to-BMC mappings from BMC credentials for several reasons:

  • Multi-tenant deployments: Multiple VMs/nodes can share the same BMC (blade servers, virtualized environments)
  • Credential reuse: Same BMC credentials can be shared across multiple node mappings
  • Operational flexibility: Easy to reassign nodes to different BMCs without credential changes
nodes:
  baremetal-worker-1: bmc-1
  baremetal-worker-2: bmc-2
  vm_worker-3: BMC_2_VM
  vm_worker-4: BMC_2_VM

bmcs:
  bmc-1:
    endpoint: "https://192.168.1.100"
    username: "admin"
    password: "secret"
    insecure: true  # TLS verification

  bmc-2:
    endpoint: "https://192.168.1.101"
    username: "admin"
    password: "secret456"
    insecure: false               # Verify TLS certificates

  BMC_2_VM:
    endpoint: "https://192.168.1.103"
    username: "admin"
    password: "secret456"
    insecure: false

Collection Strategy

The Redfish service implements a on-demand collection with caching:

On Demand Collection Mode with Caching

  • No background collection or periodic polling
  • Direct BMC API calls during Prometheus scrape via Power()
  • Implements simple caching with staleness-based expiration to support multiple Prometheus scrapes in a short period (High Availability)
  • Returns cached data if available and fresh, otherwise collects fresh data
  • Returns all chassis with detailed PowerControl readings in a single call
  • Each PowerControl entry identified by chassis_id, power_control_id, and power_control_name for granular metric labeling

Multiple Chassis and PowerControl Support

  • Power() method returns *PowerReading (single reading containing multiple chassis with detailed PowerControl data)
  • PowerReading struct contains []Chassis slice, each with ID and []Reading for individual PowerControl entries
  • Iterates through all available chassis on the BMC and their PowerControl arrays
  • Filters and returns only PowerControl entries with valid power readings
  • Each reading includes ControlID, Name, and Power for granular power domain monitoring
  • Exposes individual PowerControl entries as separate metrics (e.g., Server Power Control, CPU Sub-system Power, Memory Power)

Metrics

Platform-level metrics are introduced as a separate metric namespace to distinguish from node-level power attribution. While Kepler's existing metrics attribute power consumption to workloads running on a node, platform metrics represent individual power domains from the underlying bare metal server (via BMC), regardless of whether Kepler runs on bare metal or within a VM.

PowerControl Granularity: Each PowerControl entry from the BMC's PowerControl array is exposed as an individual metric with detailed labels. This approach avoids making assumptions about power topology (whether PowerControl entries should be summed or represent independent power domains) and allows users to understand their specific hardware's power structure.

This separation enables:

  • Multiple VMs on the same bare metal to report the same platform power
  • Clear distinction between attributed workload power and platform power domains
  • Granular monitoring of power subsystems (CPU, memory, storage, etc.)
  • Flexible aggregation based on understanding of specific hardware topology

Important: This implementation uses a power-only (Watts) approach. Energy counters (kepler_platform_joules_total) are not supported because:

  • Redfish does not provide native energy counters
  • Collection frequency varies based on demand and configuration
# Platform power metrics (bare metal power consumption) - individual PowerControl entries exposed
kepler_platform_watts{source="redfish",node_name="worker-1",bmc_id="bmc-1",chassis_id="System.Embedded.1",power_control_id="PC1",power_control_name="Server Power Control"} 450.5
kepler_platform_watts{source="redfish",node_name="worker-1",bmc_id="bmc-1",chassis_id="System.Embedded.1",power_control_id="PC2",power_control_name="CPU Sub-system Power"} 85.2
kepler_platform_watts{source="redfish",node_name="worker-1",bmc_id="bmc-1",chassis_id="Enclosure.Internal.0-1",power_control_id="PC1",power_control_name="Enclosure Power Control"} 125.3

# Existing node metrics unchanged (workload attribution)
kepler_node_cpu_watts{zone="package",node_name="worker-1"} 125.2

Error Handling

  • Connection failures: Log errors and continue to run (instead of terminating)
  • Authentication errors: Retry once, then disable for node
  • Timeouts: Configurable HTTP client timeout for BMC requests (default 5 seconds)
  • Individual chassis failures: Skip failed chassis and continue with available ones
  • Graceful degradation when BMCs unavailable

Security

  • Credentials in Kubernetes secrets or secure files (mode 0600)
  • No credential logging
  • Require explicit opt-in via configuration

Implementation Status

✅ Implemented and Available (Experimental):

  1. Core: Full Gofish integration with simplified on-demand power collection and service interfaces
  2. Metrics: Platform collector integrated with Prometheus exporter
  3. Configuration: CLI flags and YAML configuration with automatic node ID resolution
  4. Testing: Unit tests with mock server covering multiple vendor scenarios
  5. Caching: Staleness-based caching to reduce BMC API calls
  6. Multiple Chassis and PowerControl: Support for collecting detailed power data from all chassis and individual PowerControl entries

Current State:

  • Feature is experimental and requires explicit opt-in via configuration
  • All described functionality is implemented and tested
  • Available for use in controlled environments
  • Simplified architecture reduces complexity while providing core functionality

Implementation Phases

  1. Core: Gofish integration, power collection, service interface ✅
  2. Metrics: Platform collector, Prometheus registration ✅
  3. Testing: Unit, integration, multi-vendor validation ✅
  4. Release: Documentation, migration guides ✅

Testing Strategy

Implemented Testing:

  • Unit tests: Full test coverage with mocked Redfish responses
  • Mock server: HTTP server simulating BMC Redfish API endpoints for different vendors
  • Multi-vendor scenarios: Dell, HPE, Lenovo, and Generic response variations
  • Error conditions: Connection failures, authentication errors, timeouts, missing chassis
  • Concurrency testing: Race detection and thread safety validation
  • Caching behavior: Staleness-based caching and cache expiry testing
  • Service lifecycle: Complete Init, ChassisPower, and Shutdown testing

Testing Infrastructure:

  • Mock Redfish server with configurable response scenarios and error injection
  • Test data validation helpers and assertion functions
  • Race condition testing with go test -race
  • Service lifecycle testing covering all service interfaces
  • Configuration validation and error handling tests
  • BMC configuration file loading and node mapping tests

Performance Validation:

  • On-demand collection with caching reduces BMC load
  • Simplified architecture minimizes overhead
  • Multiple chassis data collected in single BMC interaction
  • Built-in staleness management to optimize performance

Migration

  • Backward Compatible: No breaking changes, opt-in feature
  • Phased Rollout: Test subset before full deployment
  • Rollback: Disable via config flag, continues with RAPL-only

Risks and Mitigations

Risk Mitigation
BMC connectivity Retry logic, graceful degradation
Vendor compatibility Multi-vendor testing
Performance impact <2% overhead validation
Security Secure credential handling, TLS default

Experimental Maturity

Why Experimental:

  • First implementation of BMC integration in Kepler
  • Multi-vendor compatibility needs broader testing
  • Performance impact requires real-world validation
  • Configuration patterns may evolve based on user feedback

Path to Stable:

  1. Field Testing: Deploy in controlled environments
  2. Vendor Validation: Test with additional BMC implementations
  3. Performance Analysis: Measure production impact and optimization
  4. Community Feedback: Iterate based on user experience
  5. API Stabilization: Finalize configuration and metric structures

Current Limitations:

  • Power-only metrics (no energy counters due to intermittent BMC polling)
  • Basic staleness-based caching (more advanced cache management could be added)
  • BMC calls during Prometheus scrape when cache is stale (mitigated by built-in caching)
  • Tested with mock servers (Dell, HPE, Lenovo, Generic scenarios)

Future Enhancements

  • Background collection with better caching for improved performance
  • Enhanced cache management and retry logic
  • Circuit breaker patterns for BMC failure handling
  • External secret integration (Kubernetes, Vault)
  • Chassis sub-component power zones (PSU, fans, storage)
  • Energy counter derivation for long-term monitoring
  • Additional BMC authentication methods

Open Questions

  1. ~~Multi-chassis server handling for complex hardware?~~ Addressed: ChassisPower() returns all chassis with power readings
  2. ~~Need for caching layer in future versions?~~ Addressed: Simple caching layer implemented
  3. Sub-component power exposure (PSU, fans) priority?
  4. Integration with other platform monitoring tools?
  5. Performance impact of BMC calls during Prometheus scrape (mitigated by caching)?
  6. Better cache management strategies for high-frequency monitoring?

Copyright Contributors to the Kepler's project.